Setup ONTAP for Cinder

Setup ONTAP for Cinder

This section provides an example set of configuration commands to be executed within ONTAP that enables two SVMs, appropriately configured for the Cinder configuration referenced in the section called “Sample cinder.conf”. Note that you may have to edit IP addresses and feature lists based on the environment and licenses present.

Licenses

Assign licenses

license add --license-code xxxxxxxxxxxxxx

license add --license-code xxxxxxxxxxxxxx

Aggregates

Create aggrs

storage aggregate create -aggregate aggr1 -diskcount 24 -nodes \
democluster-1-01

storage aggregate create -aggregate aggr2 -diskcount 24 -nodes \
democluster-1-02

Storage Virtual Machines

Create SVMs

vserver create -vserver demo-iscsi-svm -rootvolume vol1 \
-aggregate aggr1 -ns-switch file -rootvolume-security-style unix

vserver create -vserver demo-nfs-svm -rootvolume vol1 \
-aggregate aggr2 -ns-switch file -rootvolume-security-style unix

Configure iSCSI

Setup iSCSI

iscsi create -vserver demo-iscsi-svm

Setup networking

network interface create -vserver demo-iscsi-svm -lif \
demo-iscsi-data -role data -data-protocol iscsi -home-node \
democluster-1-01-e0e -home-port e0e -address 10.63.40.149 \
-netmask 255.255.192.0

network interface create -vserver demo-iscsi-svm -lif \
demo-iscsi-data-e0f -role data -data-protocol iscsi -home-node \
democluster-1-01 -home-port e0f -address 10.63.40.150 \
-netmask 255.255.192.0

network interface create -vserver demo-iscsi-svm -lif \
demo-iscsi-data-e0e -role data -data-protocol iscsi -home-node \
democluster-1-02 -home-port e0e -address 10.63.40.151 \
-netmask 255.255.192.0

network interface create -vserver demo-iscsi-svm -lif \
demo-iscsi-data-e0f -role data -data-protocol iscsi -home-node \
democluster-1-02 -home-port e0f -address 10.63.40.152 \
-netmask 255.255.192.0

Setup volume

volume create -vserver demo-iscsi-svm -volume vol1 \
-aggregate aggr1 -size 1024g

volume create -vserver demo-iscsi-svm -volume vol2 \
-aggregate aggr1 -size 1024g

volume create -vserver demo-iscsi-svm -volume vol3 \
-aggregate aggr1 -size 1024g

volume create -vserver demo-iscsi-svm -volume vol4 \
-aggregate aggr1 -size 1024g

volume create -vserver demo-iscsi-svm -volume vol5 \
-aggregate aggr2 -size 1024g

volume create -vserver demo-iscsi-svm -volume vol6 \
-aggregate aggr2 -size 1024g

volume create -vserver demo-iscsi-svm -volume vol7 \
-aggregate aggr2 -size 1024g

volume create -vserver demo-iscsi-svm -volume vol8 \
-aggregate aggr2 -size 1024g

Configure NFS

Setup NFS

nfs create -vserver demo-nfs-svm -access true

Setup networking

network interface create -vserver demo-nfs-svm -lif node1-nfs-e0c \
-role data -home-node democluster-1-01 -home-port e0c -address \
10.63.41.149 -netmask 255.255.192.0

network interface create -vserver demo-nfs-svm -lif node1-nfs-e0d \
-role data -home-node democluster-1-01 -home-port e0d -address \
10.63.41.150 -netmask 255.255.192.0

network interface create -vserver demo-nfs-svm -lif node2-nfs-e0c \
-role data -home-node democluster-1-02 -home-port e0c -address \
10.63.41.149 -netmask 255.255.192.0

network interface create -vserver demo-nfs-svm -lif node2-nfs-e0d \
-role data -home-node democluster-1-02 -home-port e0d -address \
10.63.41.150 -netmask 255.255.192.0

Setup export policy rule

vserver export-policy rule create -vserver demo-nfs-svm \
-policyname default -clientmatch 0.0.0.0/0 -rorule any -rwrule \
any -superuser any -anon 0

Setup volume

volume create -vserver demo-nfs-svm -volume vol1_dedup \
-aggregate aggr1 -size 1024g -junction-path /vo1_dedup

volume create -vserver demo-nfs-svm -volume vol2_compressed \
-aggregate aggr1 -size 1024g -junction-path /vol2_compressed

volume create -vserver demo-nfs-svm -volume vol3_mirrored \
-aggregate aggr1 -size 1024g -junction-path /vol3_mirrored

volume create -vserver demo-nfs-svm -volume vol3_mirror_dest \
-aggregate aggr2 -size 1024g -type DP

SSC features

volume efficiency on -vserver demo-nfs-svm -volume vol1_dedup

volume efficiency on -vserver demo-nfs-svm -volume vol2_compressed

volume efficiency modify -vserver demo-nfs-svm -volume \
vol3_compressed -compression true -inline-compression true

snapmirror create -source-path demo-nfs-svm:vol3_mirrored \
-destination-path demo-nfs-svm:vol3_mirror_dest -type DP \
-vserver demo-nfs-svm

snapmirror initialize -source-path demo-nfs-svm:vol4_mirrored \
-destination-path demo-nfs-svm:vol4_mirror_dest -type DP

Enable NFS v4.0, v4.1, pNFS

nfs modify -vserver demo-nfs-svm -v4.0 enabled -v4.1 enabled \
-v4.1-pnfs enabled